info@adventelectric.co.in +91 9811777747

FIXED EXTINGUISHING SYSTEM

with FireCease FK-5-1-12

UL Listed Extinguishing Agent

PROTECTION THAT MAKES THE DIFFERENCE

The fire protection systems industry is fast-paced and driven by technology, delivering high added value in line with the benefits it provides: occupational safety and operational continuity for industries, businesses and services.

With a growing need to improve the performance of traditional systems, the latest generation of extinguishing gases introduces new technologies, reducing fire damage and improving sustainable use. The FireCease FK-5-1-12 agent is a clean gas, especially suitable for protecting sensitive and/or valuable goods.

It acts swiftly in target areas – while the outbreak is in its initial phase – to suppress fire without damaging equipment. Its early detection capability reduces fire, smoke or particulate damage, as well as the collateral damage caused by alternative suppression agents, such as water, chemical powders or aerosols.

FireCease FK-5-1-12 is doubly clean: as the least polluting chemical gas on the market, it leaves no residue and is environmentally friendly, leading to zero deterioration of the ozone layer and minimal greenhouse effects.

Safety and efficiency for people, goods and the environment

Electrical, electronic, IT, industrial, and other key systems are vulnerable to fire and the collateral damage from an outbreak (smoke, soot, water damage from sprinklers or fire hoses). Moreover, the use of a system that is safe for sensitive equipment helps to properly protect valuable items in storage

Industry increasingly relies on the continuous operation of sensitive electronic devices, which means they must be protected from failure.

In the event of an outbreak, the business losses from an interruption in the services provided by these components must be added to the direct cost of repair or replacement of the affected equipment. Such interruptions can lead to a complete shutdown of company operations.

FireCease FK-5-1-12 Agent

System that fulfils maximum expectations

We offer the full spectrum of services to help companies for fire safety. Everything from creating standards of excellence to training your people to work in more effective ways, assessing how you’re doing, and helping you even better. Very few others do this, and none have been doing it as long as we have.

Clean

The FireCease FK-5-1-12 extinguishing gas is a CLEAN agent: it does not leave ANY residue after discharge, nor does it produce significant overpressure in enclosures.

Leaves no residue

It acts by totally flooding the enclosure, which means its necessary to guarantee the rated concentration over length of time. It does not reduce oxygen, emit noisy discharges favoring safe evacuation.

Colorless & Odorless

It is a colorless, odorless, non-conductive composite with a water-like appearance, suitable for solid fuel fires, flammable liquids or energized electric fires.

Electrically non-conductive

It is designed to protect sensitive installations like museums, libraries where water would cause severe damage.

The FireCease FK-5-1-12 fire suppression systems are pressurized with dry nitrogen to 25 or 42 bar.
FireCease FK-5-1-12 at 42 bar

At this pressure, non-welded cylinders can be used, while pipes can cover greater distances with higher discharge levels. Extremely useful for complex networks or for protection of medium and large enclosures.

In addition, we offer the widest range of cylinder capacities on the market, meaning our clients can match their investments to their precise needs

Our systems are compact and optimized, allowing our clients to minimize the installed system footprint thanks to the ability to tailor the load size and piping layout for the liquefied gas, pressurized with dry nitrogen, to exact design needs.

S-FLOW

SUPERIOR DISCHARGE PERFORMANCE

The FireCease 1230 system deliver optimal discharge performance, allowing maximum adjustment and optimization for any design.

FireCease FK-5-1-12 S-FLOW at 32 / 34 bar:

The use of low pressures of up to 34 bar allows increasing distance and discharge flow without increasing overall system costs, yielding improved performance without sacrificing budget objectives.

FireCease FK-5-1-12 S-FLOW at 50 bar:

High-pressure designs can reach maximum capacity, covering great distances of pipe within complex networks while delivering excellent discharge volume (over 1T in 10s). Our system is the ideal choice for reducing installed piping diameters (owing to increased flow) to protect large enclosures (high discharge capacity) or for centralized systems (use of directional valves with selective activation in line with enclosure size).

Other components

Our systems are compact and optimized, allowing our clients to minimize the installed system footprint thanks to the ability to tailor the load size and piping layout for the liquefied gas, pressurized with dry nitrogen, to exact design needs.

Siex tests and approves all the required and/or optional devices deployed in a customized client installation:

ACTUATORS: Electric, manual, remote manual, pneumatic, remote pneumatic, thermal, and so on.

SECURITY AND CONTROL: Load control (pressure switches, pressure gauges, weighing device), pneumatic retarder, odorizer, disable device or bleed valves, and so on.

HAZARDOUS AREAS: electrical components for explosive atmospheres.

SELECTOR VALVES: For centralized distribution of the agent to a variety of enclosures. Pneumatic apertures available up to 4".

Optimal design while ensuring complete safety.

Optional inclusion of passive or online reserves.

Call To Action

Contact Us

Have a question about the company, what we deals in, project we completed, our process, or just curious about what’s on? Feel free to reach out to us through any of the mode below

Address

Advent Electric Technologies Pvt Ltd
Y-51, Okhla Industrial Area, Phase-II Delhi 110020

Phone Number

+91 9811777747 (UP)

+91 9811001001 (Delhi)